Optimizing Windows Caching Algorithm
By default, Windows XP optimizes caching for performance
on external drives. Windows Vista and 7 optimize caching for
quick removal. As a result, Windows XP appears to have
faster access to external disks but at a greater risk of data
corruption and loss. To change Windows' caching algorithm,
open the disk management console (as described on page 8)
on your system drive.
A list of the attached
drives and their
respective volumes will
appear. Right-click on
the Fantom external
disk in the disk list and
select properties.
Select the Policies Tab
near the top left of the
window, and click your
desired optimization
level. press OK when
finished, and you may
close the disk
management applet.
Optimizing for performance can greatly enhance the
throughput of your disk but is much more vulnerable
to data loss! Make sure to have appropriate backup
strategies before enabling this feature!
RAID 1 (Mirror)
The SAFE storage policy
stores all data in duplicate on
each drives to protect against
data loss due to drive failure.
One drive mirrors the other
at all times, which means
every write operation goes to
both drives. SAFE provides
the highest level of data fault
tolerance, but halves the amount of storage capacity
because all data must be stored twice. The resulting
storage capacity of the virtual SAFE volume will be equivalent
to the size of one hard drive. If one drive fails, the SAFE
volume is still usable, but it is in a vulnerable state because
its mirrored hard drive is inaccessible. When the offline drive
is replaced, the GForce3 Mega will begins a rebuild process
immediately to restore data redundancy.
Although the volume remains available during the rebuild
process, the volume is susceptible to data loss through
damage to the remaining drive until redundancy is
restored at the end of the rebuild and verification process.
Host access takes precedence over the rebuild process. If
you continue to use the mirrored volume during the rebuild,
the rebuild process will take a longer time to complete, and
the host data transfer performance will also be affected.