FIBRE-to-SAS/SATA RAID SUBSYSTEM
User Manual
91
6.8 Sparing Strategy
It is recommended that you reserve a spare disk in the configuration of the system
for use as a replacement when a hardware error occurs on another disk in the
system. The Sparing Strategy screen is used to set (or modify) the strategy used
and to assign (or unassign) a disk as a spare.
The sparing strategies available are:
Global - A disk that can be used by any RAID on the system that has
global sparing strategy selected.
Local - A disk that can only be used by the RAID in which it was added to.
NOTE: A RAID that has a local spare cannot use the global spare.
None - The RAID selected cannot use the global spare and does not have a
local spare assigned. The RAID cannot be re-built automatically.
6.8.1 Creating a Hot Spare
Select/change a sparing strategy from the RAID Functions Î Create Hot Spare
screen as follows:
1. If a global spare is required, select the row where the Global option is
listed. If a local spare is required for a particular RAID, select the according
row by ticking the radio button for that row.